BuildingTcl -- BuildAndAnalyze

From OpenSeesWiki
Jump to navigation Jump to search

The BuildAndAnalyze command allows the user to select Models and LoadCombinations and actually perform the analyses. If this command is run from within BuildingTclViewer, the simulations will run, but no graphics will be displayed.


Commands

  • ListAllModels
Display all ModelLabels in the OpenSees window
  • ListAllLoadCombinations
Display all LoadCombinationLabels in the OpenSees window
  • SelectAllModels
turns on all switches for all ModelLabels for the subsequent BuildAndAnalyze command
  • SelectAllLoadCombinations
turns on all switches for all LoadCombinationLabels for the subsequent BuildAndAnalyze command
  • UnselectAllModels
turns off all switches for all ModelLabels for the subsequent BuildAndAnalyze command
  • UnselectAllLoadCombinations
turns off all switches for all LoadCombinationLabels for the subsequent BuildAndAnalyze command
  • SelectModel $ModelLabel1 <$ModelLabel2 ...>
turns on switches for the specified ModelLabels for the subsequent BuildAndAnalyze command
  • SelectLoadCombination $LoadCombinationLabel1 <$LoadCombinationLabel2 ...>
turns on switches for the specified LoadCombinationLabels for the subsequent BuildAndAnalyze command
  • BuildAndAnalyze
perform simulation on all ModelLabels and LoadCombinationLabels whose switch is on.


Arguments

$ModelLabel1 $ModelLabel2 …
previously-defined ModelLabels
$LoadCombinationLabel1 $LoadCombinationLabel2 …
previously-defined LoadCombinationLabels


Notes

At least one ModelLabel and one LoadCombinationLabel must be selected before the BuildAndAnalyze command, otherwise, an error will occur. Many ModelLabels and LoadCombinations can be built and analyzed consecutively with one command using the optional arguments.


Options

Examples



Return to BuildingTcl Command Language Manual