This command is used to construct a uniaxial Kent-Scott-Park concrete material object with degraded linear unloading/reloading stiffness according to the work of Karsan-Jirsa and no tensile strength. (REF: Fedeas).


uniaxialMaterial Concrete01 $matTag $fpc $epsc0 $fpcu $epsU

$matTag integer tag identifying material
$fpc concrete compressive strength at 28 days (compression is negative)*
$epsc0 concrete strain at maximum strength*
$fpcu concrete crushing strength *
$epsU concrete strain at crushing strength*

NOTE:

  • Compressive concrete parameters should be input as negative values.
  • The initial slope for this model is (2*$fpc/$epsc0)


Typical Hysteretic Stress-Strain Relation for material


Code Developed by: fmk