Example posted by:  <span style="color:blue"> Sarven Akcelyan & Dr. Dimitrios G. Lignos (McGill University)</span>
Example posted by:  <span style="color:blue"> '''''[http://sarvenakcelyan.com Sarven Akcelyan]''''' & '''''[http://dimitrios-lignos.research.mcgill.ca/PLignos.html Prof. Dimitrios G. Lignos]''''' (McGill University)</span>


----
----
Line 18: Line 18:
[[File:Viscous-Fig1.jpg|300px|thumb|left|Figure 1.  Schematic representation of a viscous damper installed in the single story moment resisting frame.]]
[[File:Viscous-Fig1.jpg|300px|thumb|left|Figure 1.  Schematic representation of a viscous damper installed in the single story moment resisting frame.]]


The viscous damper is modeled with a [[Two Node Link Element|Two Node Link Element]]. This element follows a [[Maxwell Material| Viscous damper]] hysteretic response.  An idealized schematic of the model is presented in Figure 1.
The viscous damper is modeled with a [[Two Node Link Element|Two Node Link Element]]. This element follows a [[ViscousDamper Material| Viscous damper]] hysteretic response.  An idealized schematic of the model is presented in Figure 1.


The units of the model are mm, kN, and seconds.
The units of the model are mm, kN, and seconds.
Line 28: Line 28:
=== Damper Links ===
=== Damper Links ===


[[Two Node Link Element|A Two Node Link Element]]] is used to link the two nodes that define the geometry of the viscous damper.
[[Two Node Link Element|A Two Node Link Element]] is used to link the two nodes that define the geometry of the viscous damper.


=== Constraints ===
=== Constraints ===
Line 36: Line 36:


To model the viscous damper the [[ViscousDamper Material| ViscousDamper]] is used. The input parameters that are selected for the damper example are as follows:
To model the viscous damper the [[ViscousDamper Material| ViscousDamper]] is used. The input parameters that are selected for the damper example are as follows:
Axial Stiffness K = 25 kN/mm, Viscous Coefficient Cd=20.74 kN(s/mm)<sup>0.35</sup> and exponent a=0.35.
Axial Stiffness K = 25 kN/mm, Damping Coefficient Cd=20.74 kN(s/mm)<sup>0.35</sup> and exponent a=0.35.


=== Loading ===
=== Loading ===
The single story frame with viscous damper is subjected to the unscaled JR Takatori record from the Kobe 1995 earthquake in Japan.  
The single story frame with viscous damper is subjected to the 50% JR Takatori record from the Kobe 1995 earthquake in Japan.  


=== Recorders ===
=== Recorders ===
Line 47: Line 47:


=== Analysis ===
=== Analysis ===
A uniform excitation option is selected with application of ground acceleration history as the imposed motion. The Newmark integration scheme is selected for integration of the equations of motion with a time step dt = 0.001sec. Note that small integration steps may be are necessary to achieve convergence. Two percent mass proportional damping is used.
A uniform excitation option is selected with application of ground acceleration history as the imposed motion. The Newmark integration scheme is selected for integration of the equations of motion with a time step dt = 0.001sec. Two percent mass proportional damping is used.




== Results ==
== Results ==
=== Simulation Results for the 100% JR Takatori Record ===
=== Simulation Results for the 50% JR Takatori Record ===
[[File:Viscous-Fig2.png|700px|thumb|left|Figure 2.  Displacement history at the roof of the single story MRF]]
[[File:Viscous-Fig2.png|700px|thumb|left|Figure 2.  Displacement history at the roof of the single story MRF]]


* The force - displacement relationship from the viscous damper are shown in Figure 3. A comparison with results from a SAP2000 model is also shown in Figure 3. Results are nearly identical between the two models.
* The force - displacement relationship from the viscous damper are shown in Figure 3. A comparison with results from a SAP2000 model is also shown in Figure 3. Results are nearly identical between the two models.


[[File:Viscous-Fig3.png|500px|thumb|left|Figure 3.  Force - displacement relationship of the viscous damper and comparison with identical model in SAP2000]]
[[File:Viscous1-Fig3.png|500px|thumb|left|Figure 3.  Force - displacement relationship of the viscous damper and comparison with identical model in SAP2000]]

Latest revision as of 06:23, 17 June 2018

Example posted by: Sarven Akcelyan & Prof. Dimitrios G. Lignos (McGill University)


This example demonstrates how to use the viscous damper material within a simple single story shear frame.

The files needed to analyze this structure in OpenSees are included here:

Supporting files

  • TakY.th – uses the JR Takatori record from the Kobe 1995 earthquake (available in the zip file below)

All files are available in a compressed format here: Viscous_Damper_Example.zip

The rest of this example describes the model and shows the analysis results.

Model Description

Figure 1. Schematic representation of a viscous damper installed in the single story moment resisting frame.

The viscous damper is modeled with a Two Node Link Element. This element follows a Viscous damper hysteretic response. An idealized schematic of the model is presented in Figure 1.

The units of the model are mm, kN, and seconds.


Basic Geometry

The single bay single story frame shown in Figure 1 has 5000mm bay width and 3000mm story height (centerline). The period of the system is 0.7sec. Columns and beams of the frame are modeled with elastic beam-column elements.

Damper Links

A Two Node Link Element is used to link the two nodes that define the geometry of the viscous damper.

Constraints

the Nodes at the base of the frame are fixed. The beam (element 3 in Figure 1) is considered to be rigid.

Viscous Damper Material

To model the viscous damper the ViscousDamper is used. The input parameters that are selected for the damper example are as follows: Axial Stiffness K = 25 kN/mm, Damping Coefficient Cd=20.74 kN(s/mm)0.35 and exponent a=0.35.

Loading

The single story frame with viscous damper is subjected to the 50% JR Takatori record from the Kobe 1995 earthquake in Japan.

Recorders

The recorders used in this example include:

  • The Element recorder to track the damper axial force and axial displacement.
  • The Node recorder to track the Frame displacement history at its roof.

Analysis

A uniform excitation option is selected with application of ground acceleration history as the imposed motion. The Newmark integration scheme is selected for integration of the equations of motion with a time step dt = 0.001sec. Two percent mass proportional damping is used.


Results

Simulation Results for the 50% JR Takatori Record

Figure 2. Displacement history at the roof of the single story MRF
  • The force - displacement relationship from the viscous damper are shown in Figure 3. A comparison with results from a SAP2000 model is also shown in Figure 3. Results are nearly identical between the two models.
Figure 3. Force - displacement relationship of the viscous damper and comparison with identical model in SAP2000